Skip to main content
  • Poster Presentation
  • Open access
  • Published:

Realtime tuning and verification of compartmental cell models using RTXI and GENESIS

The GEneral NEural SImulation System (GENESIS) has recently been reconfigured to resolve problems resulting from the rapidly increasing complexity of neural modeling software. Modularization of GENESIS according to the Computational Biology Initiative (CBI–[1]) functional software architecture has provided important advantages by facilitating the easy integration of new simulator functionality while maintaining an open developer community. The complexity of individual software modules is greatly reduced from that of a complete simulation system, documentation is simplified when modules are independent, they can be more easily tested, added or removed, and the scope of a new module is clearly delineated. Unlike GENESIS versions 1 and 2, the modular construction of GENESIS-3 (G-3) is designed to greatly facilitate the development of new tools to support simulation-based education, collaboration, and model publication.

The Real-Time eXperimental Interface (RTXI) is a mature modular dynamic clamp implementation growing out of previous work by Butera [2] and White [3] for hard realtime (RT) data acquisition. RTXI is modular to the extent that user-supplied function-specific code models can be combined to build custom experimental protocols and interfaces. RTXI provides an event delivery system that allows these plug-ins to signal the occurrence of user-defined events amongst themselves as required.

We report on our efforts to interface G-3 with RTXI to develop an integrated software platform. This platform will greatly increase the power of dynamic clamp technology and in return deliver RT quantification and ’tuning’ of the parameters of cell and tissue models. Figure 1.

figure 1

Figure 1

References

  1. Cornelis H, Edwards M, Coop AD, Bower JM: The CBI architecture for computational simulation of realistic neurons and circuits in the GENESIS 3 software federation. BMC Neurosci. 2008, 9 (S1): 88-10.1186/1471-2202-9-S1-P88.

    Article  Google Scholar 

  2. Butera RJ, Wilson CG, Delnegro CA, Smith JC: A methodology for achieving high-speed rates for artificial conductance injection in electrically excitable biological cells. IEEE Trans Biomed Eng. 2001, 48: 1460-1470. 10.1109/10.966605.

    Article  PubMed  Google Scholar 

  3. Dorval AD, Christini DJ, White T, Real-time linux dynamic clamp: A fast and flexible way to construct virtual ion channels in living cells. Ann. Biomed. Eng. 2001, 29: 897-907. 10.1114/1.1408929.

    Article  CAS  PubMed  Google Scholar 

Download references

Acknowledgements

This research was supported by a NSF grant (HRD-0932339) to the University of Texas at San Antonio.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Hugo Cornelis.

Rights and permissions

Open Access This article is published under license to BioMed Central Ltd. This is an Open Access article is distributed under the terms of the Creative Commons Attribution 2.0 International License (https://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Reprints and permissions

About this article

Cite this article

Cornelis, H., Coop, A.D. Realtime tuning and verification of compartmental cell models using RTXI and GENESIS. BMC Neurosci 11 (Suppl 1), P68 (2010). https://doi.org/10.1186/1471-2202-11-S1-P68

Download citation

  • Published:

  • DOI: https://doi.org/10.1186/1471-2202-11-S1-P68

Keywords