Study | Syam et al. [53] | Li [52] | Fedeli et al. [54] |
---|---|---|---|
TR | 62.2 ms | – | 36 ms |
TR/TE | – | 28/23 ms | – |
Flip angle | 15º | 15° | 20° |
Bandwidth | – | – | – |
FOV | – | 230 × 230 × 180 mm3 | – |
Matrix size | – | 256 × 256 × 180 | 512 × 512 |
Slice thickness | 2 mm | – | – |
Slice numbers | – | – | – |
TEs | 5 echoes Range: 5.7–29.5 ms | – | 5/12/19/26/33 ms |
Total time | – | – | – |
Sequence | 3D multi-echo gradient-echo (mGRE) | SWI with velocity-compensated 3D fast-field echo | 3D spoiled multi-echo GRE sequences (mGRE) |
Participants | 26 Patients with PD, 27 Patients with PSP, and 26 healthy subjects | 31 Non-demented PD patients, 10 patients with PDD and 27 healthy subjects | 26 Patients 26 patients with primary atypical Parkinsonisms,and 49 patients with PD |
MRI scanner system | 3T MRI System (Discovery MR 750w, GE Healthcare, USA) | 3.0T MRI System (Philips Achieva) | 3T MRI System (Philips Achieva) |
Study | Ide et al. [55] | Li et al. [73] | Shahmaei et al. [51] |
---|---|---|---|
TR | 58.4Â ms | 32.80Â ms | 38Â ms |
TR/TE | – | – | – |
Flip angle | 15° | – | 15° |
Bandwidth |  ± 62.5 Hz | – | 704 Hz/pixel |
FOV | 22 × 16.5 cm2 | 240 × 240 mm2 | 256 mm |
Matrix size | 320 × 416 | 320 × 320 | 256 × 256 |
Slice thickness | 1.5 mm | – | 1.5 mm |
Slice numbers | 1848 | – | – |
TEs | 11 echoes TE1 = 4.5 ms Time spacing = 5 ms | 11.00 ms | 4, 41.8 ms |
Total time | 7 min 1 s | 528 s | 9 min |
Sequence | 3D multi-echo spoiled gradient echo (mGRE) | multi-echo GRE sequence (mGRE) | GRE T2* |
Participants | 19 Patients with PD and 41 healthy subjects | 3 Patients with schizophrenia, 4 patients with dystonia, and 5 patients with Parkinson’s disease | 30 Patients with PD and 15 healthy subjects |
MRI scanner system | 3T MRI System equipped with 8-channel phased-array coil | 3T MRI System equipped with a 24-channel head coil | 3T MRI System (Tim Trio Siemens Healthcare, Erlangen, Germany) With 32-channel coil |