Skip to main content

Table 1 Mean hit and false alarm rates and reaction times for all conditions

From: Driving steady-state visual evoked potentials at arbitrary frequencies using temporal interpolation of stimulus presentation

Condition

Hits

False alarms

Reaction time

10.0 Hz at 85 Hz (Interp.)

93.2 (1.8)  %

10.5 (3.4)  %

495.3 (7.9) ms

10.6 Hz at 85 Hz (Non-interp.)

93.3 (1.1)  %

10.4 (2.7)  %

493.7 (8.9) ms

14.1 Hz at 85 Hz (Non-interp.)

92.0 (1.7)  %

10.8 (3.4) %

494.5 (6.2) ms

15.0 Hz at 85 Hz (Interp.)

92.0 (1.8)  %

10.7 (3.3) %

506.2 (9.9) ms

10.0 Hz at 120 Hz (Non-interp.)

93.3 (1.4)  %

10.2 (2.6)  %

490.5 (8.7) ms

10.6 Hz at 120 Hz (Interp.)

95.0 (1.2)  %

8.9 (2.2) %

489.9 (8.1) ms

14.1 Hz at 120 Hz (Interp.)

92.7 (1.4)  %

9.9 (2.9)  %

486.2 (7.1) ms

15.0 Hz at 120 Hz (Non-interp.)

94.4 (1.2)  %

11.1 (3.0)  %

490.4 (7.0) ms

Average

93.2 (1.2)  %

10.3 (2.8)  %

493.3 (7.0) ms

 F

1.325

0.361

2.022

 p

0.274

0.774

0.103

 η2

8.6 %

2.5 %

12.6 %

  1. Values in brackets indicate standard errors of the mean. None of the three measures of behavioral performance differed between experimental conditions